  • What is the reason for high frequency after medium frequency startup
  • 2018/1/6 number of times read:[892]
  • Failure phenomenon: can start, after the start of the successful frequency is much higher than the original, sometimes bad start.

    Fault analysis and processing: This is most of the load problem.


    There is a short circuit between the turns of the A. load coils. It is possible to overlap between lines or have conductive iron and copper wires.


    The B. load capacitor has the column opening, or the capacitive connection line has serious fire, which causes the internal capacity change.